Liquid Scanner to Identify Chemical Contents2018-08-13T19:39:27+00:00

Home » Liquid Scanner to Identify Chemical Contents

Features

  • Easily identify the chemical composition of liquids
  • Works with a variety of containers and materials including bottles, cans, and cups
  • No radiation emission, safe to be around
  • Ultra-wideband pulse microwave reflection method & the thermal conductivity technology
  • Detects over 30 types of hazardous liquids
  • LED and audible alarm
  • 2 second start up time

Part Numbers

VER-LSS1 liquid scanning system stainless steel finish
VER-LSS2 liquid scanning system plastic finish

Documentation

Specifications

Basic Parameters
Identifiable Liquids gasoline, kerosene, diesel oil, hydrochloric acid, sulfuric acid, nitric acid, sodium hydroxide, potassium hydroxide, isopropyl ether, petroleum ether, propionaldehyde, benzene, carbon disulfide, hexane, isopropanol, nitromethane, diethylamine, trihalomethanes, ethylene glycol, xylene and other flammable, corrosive liquids
Detectable Liquid Container Material metal, glass and ceramic
Detectable Liquid Container Specifications plastic, glass and ceramic / metal
volume: minimum 3.38oz [100ml] heigh: minimum 1.18″ [3cm] diameter: 1.18″ to 7.87″ [3cm to 20cm] (plastic, glass ceramic) / 1.18″ to 5.9″ [3cm to 15cm] (metal)
wall thickness: maximum 0.02″ [0.5mm]
Minimum Liquid Detection Requirements volume: 3.38oz [100ml] heigh: 1.18″ [3cm]
Explosives And Drugs Samples new samples can be added as needed
Startup Time 2 seconds (no warm-up required)
Analysis Time plastic, glass and ceramic container: less than 1 seconds
metal container: less than 5 seconds
False Alarm Rate less than 1%
Detection Rate more than 99%
Other Features
Detection Method method 1: ultra wide band pusle microwave reaction
method 2: thermal conductivity
Alarm sound, light and screen
Display LCD screen with adustable brightness
Parameter Settings adjustable
Precision Settings adjustable
Self-checking Function standard
Electrical
Operating Voltage 110Vac/220Vac (±10%) (specify at time of order)
Power Consumption 20W
Environmental
Operating Temperature 14°F to 122°F [-10°C to 50°C]
Storage Temperature 14°F to 122°F [-10°C to 50°C]
Operating Humidity up to 90% (non-condensing)
Storage Humidity up to 95% (non-condensing)
Working Pressure 86kPa to 106kPa
Physical Characteristics
Size 13.75″(W) x 15.75″(D) x 7.75″(H)
35cm(W) x 40cm(D) x 19.5cm(H)
Weight 20lbs [9kg] (-LSS1)
15.5lbs [7kg] (-LSS2)
General
Language English
Warrany 1 year